Skip to main content

Qualitative Assessment of a Clutch-Actuated Ankle Exoskeleton

  • Conference paper
  • First Online:
Advances in Service and Industrial Robotics (RAAD 2017)

Part of the book series: Mechanisms and Machine Science ((Mechan. Machine Science,volume 49))

Included in the following conference series:

  • 5104 Accesses

Abstract

Among the growing number of different exoskeletons, passive and quasi-passive solutions hold the upper-hand compared to powered solutions in price, accessibility, complexity, weight and user acceptance. This paper evaluates a modification of an originally passive ankle exoskeleton with an active clutch, making it quasi-passive. We developed an electric quasi-passive clutch to improve the performance of the original exoskeleton design, with the aim of mitigating the problems on the clutch engagement timing and user physiological variability. In order to evaluate the exoskeleton and the clutch operation, we performed a study where 7 users wore the exoskeleton and performed trial walks. Qualitative user feedback that focused on the device comfort, users perception of exoskeletons effect and smoothness of the clutch operation was collected, along with quantitative data on clutch operation during walking on a flat surface. Results show improved and more reliable exoskeleton clutch operation which was also expressed in qualitative user feedback.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Dollar AM, Herr H (2008) Lower extremity exoskeletons and active orthoses: challenges and state-of-the-art. IEEE Trans Rob 24(1):144–158

    Article  Google Scholar 

  2. Exoskeleton Report (2016) Exoskeleton catalog. http://exoskeletonreport.com/product-category/exoskeleton-catalog/. Accessed 23 Jan 2016

  3. Ferris DP et al (2005) Powered lower limb orthoses for gait rehabilitation. Top Spinal Cord Inj Rehabil 11(2):34

    Article  Google Scholar 

  4. Asbeck AT, Rossi SMMD, Galiana I, Ding Y, Walsh CJ (2014) Stronger, smarter, softer: next-generation wearable robots. IEEE Rob Autom Mag 21:22–33

    Article  Google Scholar 

  5. Gams A, Petrič T, Debevec T, Babič J (2013) Effects of robotic knee exoskeleton on human energy expenditure. IEEE Trans Biomed Eng 60(6):1636–1644

    Article  Google Scholar 

  6. Jimenez-Fabian R, Verlinden O (2012) Review of control algorithms for robotic ankle systems in lower-limb orthoses, prostheses, and exoskeletons. Med Eng Phys 34(4):397–408

    Article  Google Scholar 

  7. Zhang J, Cheah CC, Collins SH (2015) Experimental comparison of torque control methods on an ankle exoskeleton during human walking. In: IEEE international conference on robotics and automation (ICRA). IEEE, pp 5584–5589

    Google Scholar 

  8. Ekso bionics (2016) EksoWorks exoskeleton. http://eksobionics.com/eksoworks/. Accessed 23 Jan 2016

  9. Lockheed Martin (2016) Fortis exoskeleton. http://www.lockheedmartin.com/us/products/exoskeleton/industrial.html. Accessed 23 Jan 2016

  10. Alexander R (1990) Three uses for springs in legged locomotion. Int J Rob Res 9(2):53–61

    Article  Google Scholar 

  11. Chin R, Hsiao-Wecksler ET et al (2009) A pneumatic power harvesting ankle-foot orthosis to prevent foot-drop. J Neuroeng Rehabil 6(1):19

    Article  Google Scholar 

  12. Dollar AM, Herr H (2008) Design of a quasi-passive knee exoskeleton to assist running. In: IEEE/RSJ international conference on intelligent robots and systems. IEEE, pp 747–754

    Google Scholar 

  13. Elliott G, Sawicki GS, Marecki A, Herr H (2013) The biomechanics and energetics of human running using an elastic knee exoskeleton. In: 2013 IEEE international conference on rehabilitation robotics (ICORR). IEEE, pp 1–6

    Google Scholar 

  14. van Dijk W, van der Kooij H, Hekman E (2011) A passive exoskeleton with artificial tendons: design and experimental evaluation. In: IEEE international conference on rehabilitation robotics (ICORR 2011). IEEE, pp 1–6

    Google Scholar 

  15. Collins SH et al (2015) Reducing the energy cost of human walking using an unpowered exoskeleton. Nature 522(7555):212–215

    Article  Google Scholar 

  16. Diller S, Majidi C, Collins SH (2016) A lightweight, low-power electroadhesive clutch and spring for exoskeleton actuation. In: 2016 IEEE international conference on robotics and automation (ICRA). IEEE, pp 682–689

    Google Scholar 

  17. Dežman M, Debevec T, Babič J, Gams A (2017) Effects of passive ankle exoskeleton on human energy expenditure: pilot evaluation. In: Rodić A, Borangiu T (eds) RAAD 2016, vol 540. AISC. Springer, Cham, pp 491–498. doi:10.1007/978-3-319-49058-8_53

    Chapter  Google Scholar 

Download references

Acknowledgment

Partial support for this research (J.B.) was obtained from EU Horizon 2020 research and innovation programme under grant agreement No. 731540 - An.Dy.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Miha Dežman .

Editor information

Editors and Affiliations

Copyright information

© 2018 Springer International Publishing AG

About this paper

Cite this paper

Dežman, M., Babič, J., Gams, A. (2018). Qualitative Assessment of a Clutch-Actuated Ankle Exoskeleton. In: Ferraresi, C., Quaglia, G. (eds) Advances in Service and Industrial Robotics. RAAD 2017. Mechanisms and Machine Science, vol 49. Springer, Cham. https://doi.org/10.1007/978-3-319-61276-8_82

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-61276-8_82

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-61275-1

  • Online ISBN: 978-3-319-61276-8

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics

pFad - Phonifier reborn

Pfad - The Proxy pFad of © 2024 Garber Painting. All rights reserved.

Note: This service is not intended for secure transactions such as banking, social media, email, or purchasing. Use at your own risk. We assume no liability whatsoever for broken pages.


Alternative Proxies:

Alternative Proxy

pFad Proxy

pFad v3 Proxy

pFad v4 Proxy