Skip to content

STM32F405 Timer Triggering

Jay Kickliter edited this page Apr 7, 2017 · 5 revisions

The Timers can be cascaded to make more complex timing relationships, or longer periods. Internally only some timers can trigger others. This is a Master/Slave relationship and is handled by the SMS register.

For example, you can see below that TIM8 can be triggerd by TIM1.

Timer Master/Slave relationships

  • One Timer can be used as the prescaler for another.
  • The first timer update_event, or output_compare signal is used as clock for the second.
  • Uses TRGI to map.
  • Counter mode is set using the TIMx_CR1 reg and CMS bits as indicated in the example below.
  • The counter mode sets whether the update_event occurs on overflow and/or underflow of the Timer.

Example for internal trigger

Internal trigger clock mode 1 (ITRx) TIM_CLK is replaced by ITRx_CLK which is the internal trigger freq mapped to timer Trigger input TRGI.

The counter mode indicates if the update_event is generated:

  • on overflow - if mode = up counting, the DIR bit is reset in TIMx_CR1
  • on underlfow - if mode = down counting, the DIR bit is set in TIMx_CR1
  • both - if mode is center aligned, the CMS bits are non zero

The update_event is also generated by:

  • software if the UG bit (Update Generation) is set in TIM_EGR reg.
  • update generation through the slave mode controller

refer to Timer app note: DM00042534.pdf

Timer synchronisation

A Master can control a slave Timer using a Trigger TRGO. A Timer is slaved if its ITRx is connected to a Slave and the Master is set to use TRGO

Trigger outputs from the Master can be selected from:

  • Reset:
    • UG bit from EGR reg is used as TRGO
  • Enable:
    • Counter enable is used as TRGO.
    • Used to start several timers at the same time or control window for Slave start
  • Update:
    • the update_event is TRGO.
    • e.g. a master timer can act as a prescaler for a slave timer.
  • Compare pulse:
    • as soon as a capure or match occurs TRGO goes high when CC1IF flag is to be set
  • OC1REF: use OC1REF as TRGO
  • OC2REF: use OC2REF as TRGO
  • OC3REF: use OC3REF as TRGO
  • OC4REF: use OC4REF as TRGO

Master mode:

  1. Configure the Timer
  2. Select Trigger output to be used
  • in CR2 reg - set MSM bits
  1. Enable Master/slave mode
  • in SMCR reg - enable MSM bit